Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Adv ; 8(34): eabo3399, 2022 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-36007007

RESUMO

Before Perseverance, Jezero crater's floor was variably hypothesized to have a lacustrine, lava, volcanic airfall, or aeolian origin. SuperCam observations in the first 286 Mars days on Mars revealed a volcanic and intrusive terrain with compositional and density stratification. The dominant lithology along the traverse is basaltic, with plagioclase enrichment in stratigraphically higher locations. Stratigraphically lower, layered rocks are richer in normative pyroxene. The lowest observed unit has the highest inferred density and is olivine-rich with coarse (1.5 millimeters) euhedral, relatively unweathered grains, suggesting a cumulate origin. This is the first martian cumulate and shows similarities to martian meteorites, which also express olivine disequilibrium. Alteration materials including carbonates, sulfates, perchlorates, hydrated silicates, and iron oxides are pervasive but low in abundance, suggesting relatively brief lacustrine conditions. Orbital observations link the Jezero floor lithology to the broader Nili-Syrtis region, suggesting that density-driven compositional stratification is a regional characteristic.

2.
Space Sci Rev ; 217(1): 4, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33380752

RESUMO

The SuperCam instrument suite provides the Mars 2020 rover, Perseverance, with a number of versatile remote-sensing techniques that can be used at long distance as well as within the robotic-arm workspace. These include laser-induced breakdown spectroscopy (LIBS), remote time-resolved Raman and luminescence spectroscopies, and visible and infrared (VISIR; separately referred to as VIS and IR) reflectance spectroscopy. A remote micro-imager (RMI) provides high-resolution color context imaging, and a microphone can be used as a stand-alone tool for environmental studies or to determine physical properties of rocks and soils from shock waves of laser-produced plasmas. SuperCam is built in three parts: The mast unit (MU), consisting of the laser, telescope, RMI, IR spectrometer, and associated electronics, is described in a companion paper. The on-board calibration targets are described in another companion paper. Here we describe SuperCam's body unit (BU) and testing of the integrated instrument. The BU, mounted inside the rover body, receives light from the MU via a 5.8 m optical fiber. The light is split into three wavelength bands by a demultiplexer, and is routed via fiber bundles to three optical spectrometers, two of which (UV and violet; 245-340 and 385-465 nm) are crossed Czerny-Turner reflection spectrometers, nearly identical to their counterparts on ChemCam. The third is a high-efficiency transmission spectrometer containing an optical intensifier capable of gating exposures to 100 ns or longer, with variable delay times relative to the laser pulse. This spectrometer covers 535-853 nm ( 105 - 7070 cm - 1 Raman shift relative to the 532 nm green laser beam) with 12 cm - 1 full-width at half-maximum peak resolution in the Raman fingerprint region. The BU electronics boards interface with the rover and control the instrument, returning data to the rover. Thermal systems maintain a warm temperature during cruise to Mars to avoid contamination on the optics, and cool the detectors during operations on Mars. Results obtained with the integrated instrument demonstrate its capabilities for LIBS, for which a library of 332 standards was developed. Examples of Raman and VISIR spectroscopy are shown, demonstrating clear mineral identification with both techniques. Luminescence spectra demonstrate the utility of having both spectral and temporal dimensions. Finally, RMI and microphone tests on the rover demonstrate the capabilities of these subsystems as well.

3.
Space Sci Rev ; 216(8)2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33568875

RESUMO

The Mars 2020 Perseverance rover landing site is located within Jezero crater, a ∼ 50 km diameter impact crater interpreted to be a Noachian-aged lake basin inside the western edge of the Isidis impact structure. Jezero hosts remnants of a fluvial delta, inlet and outlet valleys, and infill deposits containing diverse carbonate, mafic, and hydrated minerals. Prior to the launch of the Mars 2020 mission, members of the Science Team collaborated to produce a photogeologic map of the Perseverance landing site in Jezero crater. Mapping was performed at a 1:5000 digital map scale using a 25 cm/pixel High Resolution Imaging Science Experiment (HiRISE) orthoimage mosaic base map and a 1 m/pixel HiRISE stereo digital terrain model. Mapped bedrock and surficial units were distinguished by differences in relative brightness, tone, topography, surface texture, and apparent roughness. Mapped bedrock units are generally consistent with those identified in previously published mapping efforts, but this study's map includes the distribution of surficial deposits and sub-units of the Jezero delta at a higher level of detail than previous studies. This study considers four possible unit correlations to explain the relative age relationships of major units within the map area. Unit correlations include previously published interpretations as well as those that consider more complex interfingering relationships and alternative relative age relationships. The photogeologic map presented here is the foundation for scientific hypothesis development and strategic planning for Perseverance's exploration of Jezero crater.

4.
Anesthesiology ; 130(4): 530-540, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30601218

RESUMO

WHAT WE ALREADY KNOW ABOUT THIS TOPIC: Electromagnetic interference from monopolar electrosurgery may disrupt implantable cardioverter defibrillators.Current management recommendations by the American Society of Anesthesiologists and Heart Rhythm Society are based on expert clinical opinion since there is a paucity of data regarding the risk of electromagnetic interference to implantable cardioverter defibrillators during surgery. WHAT THIS ARTICLE TELLS US THAT IS NEW: With protocolized electrosurgery dispersive electrode positioning in patients with implantable cardioverter defibrillators, the risk of clinically meaningful electromagnetic interference was 7% in above-the-umbilicus noncardiac surgery and 0% in below-the-umbilicus surgery. In cardiac surgery, clinically meaningful electromagnetic interference with use of an underbody dispersive electrode was 29%.Despite protocolized dispersive electrode positioning, the risk of electromagnetic interference in above-the-umbilicus surgery is high, supporting recommendations to suspend antitachycardia therapy when monopolar electrosurgery is used above the umbilicus.With protocolized dispersive electrode positioning, the risk of electromagnetic interference in below-the-umbilicus surgery is negligible, implying that suspending antitachycardia therapy might be unnecessary in these cases.With an underbody dispersive electrode, the risk of electromagnetic interference in cardiac surgery is high. BACKGROUND: The goal of this study was to determine the occurrence of intraoperative electromagnetic interference from monopolar electrosurgery in patients with an implantable cardioverter defibrillator undergoing surgery. A protocolized approach was used to position the dispersive electrode. METHODS: This was a prospective cohort study including 144 patients with implantable cardioverter defibrillators undergoing surgery between May 2012 and September 2016 at an academic medical center. The primary objectives were to determine the occurrences of electromagnetic interference and clinically meaningful electromagnetic interference (interference that would have resulted in delivery of inappropriate antitachycardia therapy had the antitachycardia therapy not been programmed off) in noncardiac surgeries above the umbilicus, noncardiac surgeries at or below the umbilicus, and cardiac surgeries with the use of an underbody dispersive electrode. RESULTS: The risks of electromagnetic interference and clinically meaningful electromagnetic interference were 14 of 70 (20%) and 5 of 70 (7%) in above-the-umbilicus surgery, 1 of 40 (2.5%) and 0 of 40 (0%) in below-the-umbilicus surgery, and 23 of 34 (68%) and 10 of 34 (29%) in cardiac surgery. Had conservative programming strategies intended to reduce the risk of inappropriate antitachycardia therapy been employed, the occurrence of clinically meaningful electromagnetic interference would have been 2 of 70 (2.9%) in above-the-umbilicus surgery and 3 of 34 (8.8%) in cardiac surgery. CONCLUSIONS: Despite protocolized dispersive electrode positioning, the risks of electromagnetic interference and clinically meaningful electromagnetic interference with surgery above the umbilicus were high, supporting published recommendations to suspend antitachycardia therapy whenever monopolar electrosurgery is used above the umbilicus. For surgery below the umbilicus, these risks were negligible, implying that suspending antitachycardia therapy is likely unnecessary in these patients. For cardiac surgery, the risks of electromagnetic interference and clinically meaningful electromagnetic interference with an underbody dispersive electrode were high. Conservative programming strategies would not have eliminated the risk of clinically meaningful electromagnetic interference in either noncardiac surgery above the umbilicus or cardiac surgery.


Assuntos
Desfibriladores Implantáveis/normas , Eletrodos Implantados/normas , Fenômenos Eletromagnéticos , Eletrocirurgia/normas , Marca-Passo Artificial/normas , Adulto , Idoso , Desfibriladores Implantáveis/efeitos adversos , Eletrodos Implantados/efeitos adversos , Eletrocirurgia/instrumentação , Eletrocirurgia/métodos , Feminino , Cardiopatias/fisiopatologia , Cardiopatias/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial/efeitos adversos
5.
Surgery ; 165(1): 158-165, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30415870

RESUMO

BACKGROUND: Sudden massive release of serotonin, histamine, kallikrein, and bradykinin is postulated to cause an intraoperative carcinoid crisis. The exact roles of each of these possible agents, however, remain unknown. Optimal treatment will require an improved understanding of the pathophysiology of the carcinoid crisis. METHODS: Carcinoid patients with liver metastases undergoing elective abdominal operations were studied prospectively, using intraoperative, transesophageal echocardiography, pulmonary artery catheterization, and intraoperative blood collection. Serotonin, histamine, kallikrein, and bradykinin levels were analyzed by enzyme-linked immunosorbent assay. RESULTS: Of 46 patients studied, 16 had intraoperative hypotensive crises. Preincision serotonin levels were greater in patients who had crises (1,064 vs 453 ng/mL, P = .0064). Preincision hormone profiles were otherwise diverse. Cardiac function on transesophageal echocardiography during the crisis was normal, but intracardiac hypovolemia was observed consistently. Pulmonary artery pressure decreased during crises (P = .025). Linear regression of preincision serotonin levels showed a positive relationship with mid-crisis cardiac index (r = 0.73, P = .017) and a negative relationship with systemic vascular resistance (r=-0.61, P = .015). There were no statistically significant increases of serotonin, histamine, kallikrein, or bradykinin levels during the crises. CONCLUSION: The pathophysiology of carcinoid crisis appears consistent with distributive shock. Hormonal secretion from carcinoid tumors varies widely, but increased preincision serotonin levels correlate with crises and with hemodynamic parameters during the crises. Statistically significant increases of serotonin, histamine, kallikrein, or bradykinin during the crises were not observed.


Assuntos
Hipotensão/fisiopatologia , Hipovolemia/fisiopatologia , Síndrome do Carcinoide Maligno/fisiopatologia , Artéria Pulmonar/fisiopatologia , Serotonina/sangue , Bradicinina/sangue , Tumor Carcinoide/fisiopatologia , Tumor Carcinoide/cirurgia , Ecocardiografia Transesofagiana , Feminino , Histamina/sangue , Humanos , Neoplasias Intestinais/fisiopatologia , Neoplasias Intestinais/cirurgia , Complicações Intraoperatórias , Calicreínas/sangue , Neoplasias Hepáticas/secundário , Neoplasias Pulmonares/fisiopatologia , Neoplasias Pulmonares/cirurgia , Masculino , Síndrome do Carcinoide Maligno/sangue , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Estudos Prospectivos
6.
J Leukoc Biol ; 83(2): 381-92, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17967834

RESUMO

CpG oligodeoxynucleotides (ODN) stimulate the immune system and are under evaluation as treatments and vaccine adjuvants for infectious diseases, cancer, and immune system disorders. Although they have shown promising results in numerous clinical trials, the ultimate use of CpG ODN-based therapeutics may hinge on improved pharmacokinetics and reduced systemic side-effects. CpG ODN efficacy and potency might be enhanced greatly by packaging them into particles that protect them from degradation and specifically target them for uptake by immune-competent cells. The plasma proteinase inhibitor alpha 2-macroglobulin (alpha 2M) binds numerous biologically active macromolecules, including cytokines, chemokines, and growth factors, and can modulate their activity. Molecules bound to alpha 2M are protected from interactions with neighboring macromolecules and are targeted for receptor-mediated uptake by immune-competent cells. Here, we report that activated alpha 2M (alpha 2M*) binds CpG ODN and enhances their immunostimulatory properties significantly. Murine macrophages treated with alpha 2M*-ODN complexes respond more rapidly and produce a greater cytokine response than induced by free CpG ODN. Using human PBMC, alpha 2M*-ODN complexes exhibit fourfold enhanced potency and 15-fold greater efficacy for stimulating production of inflammatory cytokines. alpha 2M* targets delivery of CpG ODN specifically to immune-competent cells, which endocytose the complexes sixfold more rapidly than free CpG ODN. CpG ODN bound to alpha 2M* are also protected from degradation by nucleases. This novel targeting technology may improve CpG ODN-based therapeutics by increasing efficacy at reduced doses, thus reducing side-effects and cost.


Assuntos
Adjuvantes Imunológicos/metabolismo , DNA/metabolismo , Proteína-1 Relacionada a Receptor de Lipoproteína de Baixa Densidade/metabolismo , Ativação de Macrófagos/efeitos dos fármacos , alfa-Macroglobulinas/metabolismo , Adjuvantes Imunológicos/farmacocinética , Adjuvantes Imunológicos/farmacologia , Animais , DNA/farmacocinética , DNA/farmacologia , Sistemas de Liberação de Medicamentos , Endocitose , Feminino , Humanos , Interferon-alfa/metabolismo , Interleucina-6/metabolismo , Elastase de Leucócito/metabolismo , Leucócitos Mononucleares/efeitos dos fármacos , Leucócitos Mononucleares/imunologia , Leucócitos Mononucleares/metabolismo , Ativação Linfocitária/efeitos dos fármacos , Macrófagos Peritoneais/efeitos dos fármacos , Macrófagos Peritoneais/metabolismo , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Níquel/farmacologia , Oligodesoxirribonucleotídeos , Receptor Toll-Like 9/deficiência , Receptor Toll-Like 9/genética , Fator de Necrose Tumoral alfa/metabolismo , alfa-Macroglobulinas/farmacocinética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...